Combustion Analyser
The KANE250 compact combustion analyser is suitable for all appliances burning natural gas, propane, butane, LPG and light oils and can also be used to accurately check CO levels in a room.
normally despatched within 2 – 3 working days…
Accurately measures O2, CO & temperature. Calculates CO2, CO/CO2 ratio & efficiency., date and time, all of which can be printed using the optional infrared printer.
Works with Multi-fuel, gases and oils.
Easy to use rotary switch
Has a detachable flue probe
Low cost of ownership
Low annual service costs and 5 year extended warranty when serviced annually by Kane
Product Features
- Measures oxygen, carbon monoxide and temperature.
- Calculates CO2, CO/CO2 ratio, excess air and boiler efficiency for gaseous fuels and light oils (28/35 sec).
- Multi fuel – Natural Gas,Propane, Butane, LPG, Light Oils (28/35 sec) and Wood Pellets
- Printer output
- Internal memory
- Fitted with protective rubber sleeve with integral magnet.
Kit contents:
- Combustion analyser
- Supplied with KMCP2 flue probe
- 4 x AA batteries
- Manual
Specification
Parameter | Resolution | Accuracy | Range |
Temp Measurement Flue Temperature
Inlet Temperature (Internal Sensor)
Temp (Nett) *2 | 1°C/F
1°C/F
1°C/F | + 2°C (5°F) +0.3% reading
+1°C/F ±0.3% reading
+ 2°C (5°F) +0.3% reading
| 0-600°C 32-1112°F
0-100°C 32-212°F
0-600°C 32-1112°F |
Gas Measurement Oxygen
Carbon Monoxide
Carbon Dioxide*2 Efficiency*2 Excess Air*2 CO/CO2 ratio*2 | 0.1%
1ppm
0.1% 0.1% 0.1% 0.001 | +0.2% *1
+10ppm <100ppm*1 +5% of reading
+0.3% reading +1.0% reading +0.2% +5% reading | 0-21%
0-1000ppm nom. 4000 ppm max for 15 minutes
0-30% 0-99.9% 0-250% 0-.9999 |
*1 Using dry gases at STP *2 Calculated
- Pre-programmed Fuels Natural gas, Light Oil (28/35 sec), Propane, Butane, LPG.
- Dimensions
- Weight 1kg (2.2lb)
- Handset 200mm (7.9") x 45mm (1.8") x 90mm (3.5")
- Probe L 300mm (11.8") x Dia 6mm (0.25") with 240mm (9.4") long stainless steel shaft,
- Type K thermocouple and 3m (6’) long neoprene hose
- Ambient Temperature 0 to +40°C (+32°F to +104°F)
- 10% to 90% RH non- condensing
- Battery Life 4 AA cells
- Typically 12 hours using Alkaline AA cells
- Charger (optional) Input: 110Vac/220 Vac nominal NiMH batteries recommended