Used by leading boiler manufacturers the KANE455 is more than just a flue gas analyser
KANE455CPA1 kit provides all the equpment required for commissioning,servicing and installing new gas appliances
Multi-fuel: Natural Gas, Propane, Butane, LPG, Light Oils (28/35 sec), and Wood Pellets
Print separate reports for: Combustion ,pressure let-by/ightness, temperature & room CO build up
CPA 1 Kit includes: Appliance sampling probe kit, gas leak detector,air/liqid probe,pressure hoses and 2 x clamp on pipe probes
- Easy to use rotay dial
- Long Life CO Sensor
- Compact boiler analyser with high accuracy pressure readings.
- Four line display controlled by 9 position rotary switch.
- Measures O2, CO2 & CO (0-2,000ppm)
- Differential pressure and differential temperature.
- Calculates CO/CO2 ratio, excess air and efficiency for multi-fuel, gaseous fuels and light oils (28/35 sec).
- Infra-red output to optional printer provides combustion, pressure, let-by/tightness, temperature and room CO build up test reports.
- gas Leak detection
- Air/liquid temperature measurement probe
- Pressure Hoses
- Clamp on pipe probes for differential temperatre measurement
- Industry approved appliance sampling probe kit
- Internal memory holds:
99 Combustion tests
20 Pressure tests
20 Tightness tests
20 Temperature tests
20 Room CO tests
- Protective rubber sleeve with magnet for “hands free” use
Kit contents:
- Analyser with protective rubber boot
- KMIRP Printer
- KMCP2 flue probe
- KAL1Air/liqid probe
- 1 x pressure hose
- 2 x KPCP Clamp on pipe probes
- 4 x NiMH rechargeable batteries
- ASP2 Appliance sampling probe kit
- Charger
- Carry case
- Manual
Parameter | Resolution | Accuracy | Range |
Temp Measurement Flue Temperature
Inlet Temperature (Internal Sensor)
External Sensor | 1°C/F
1°C/F
1°C/F | + 2°C (5°F) +0.3% reading
+1°C/F ±0.3% reading
+ 2°C (5°F) +0.3% reading
| 0-600°C 32-1112°F
0-50°C 32-120°F
0-600°C 32-1112°F |
Gas Measurement Oxygen
Carbon Monoxide
Carbon Dioxide Efficiency*2 Excess Air*2 CO/CO2 ratio*2 | 0.1%
1ppm
0.1% 0.1% 0.1% 0.001 | +0.2% *1
+10ppm <100ppm*1 +5% of reading
+0.3% reading +1.0% reading +0.2% +5% reading | 0-21%
0-2000ppm nom. 4000 ppm max for 15 minutes
0-30% 0-99.9% 0-250% 0-.09999 |
Pressure (differential) Nominal range +80mBar Maximum over range without damage to sensor is +400mBar
| Maximum 0.001 mBar <25mBar |
+0.005 mBar +0.03 mBar +3% of reading | +0.2 mBar +1 mBar +80 mBa |
1 Using dry gases at STP *2 Calculated
Pre-programmed Fuels | Natural gas, Propane, Butane, LPG Light Oils (28/35 sec), Wood Pellets |
Storage Capacity | 99 Combustion tests 20 Pressure tests 20 Tightness tests 20 Temperature tests 20 Room CO tests |
Ambient Operating Range | 0oC to +40oC 10% to 90% RH non-condensing |
Chargers (optional) | 220v charger, for NiMH batteries only 12v in-vehicle charger, for NiMH batteries only |
Dimensions Weight: Handset: Probe: | 0.8kg handset with boot 200 x 45 x 90mm 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m long neoprene hose. Type K thermocouple |