The best selling Flue Gas Analyser for all domestic boiler maintenance and measurements.
With free Testo 317-2 Gas Leak detector MRRP £111.00
The Testo 327 is a hand-held measuring instrument for the professional flue gas analysis of domestic and light commercial gas and oil boilers and appliances. This includes condensing boilers and gas heaters. The unit is designed to carry out tests shown in BS 7967, and has a timed tightness test, let by test and a timed CO function, is your introductory instrument to flue gas analysis. It measures combustion efficiency, °C, O2, CO2, CO and flue draught. The strong LED background light in the 4 line display guarantees an easy-to-read display even if lighting conditions are unfavourable. The analyser stands out on account of its easy menu navigation and ergonomic housing as well as its durability
Includes Testo 327-1 analyser, flue gas probe (180mm x 6mm diameter), mains unit, differential hose kit, differential temperature kit, Testo infrared printer and carry case
For use with natural gas, LPG, heavy and light oilMeasures; CO,CO2,O2,Ratio & EfficiencyDifferential temperature, differential pressureAmbient CO testTimed tightness and let by tests and let by testsPrint results on siteMeets all EN and BS required certifications3 year instrument and sensor warranty
Technical data Display variables [units]
Measuring range/resolution
Accuracy/response time 1)
Oxygen, via internal electro-chemical sensor (not 327 CO):
O2 content [%], O2air supply [%], Reference value O2 ref [%] 0...21% / 0.1%
±0.2% / t90 <40s
Carbon monoxide, 327-1:
CO content [ppm, mg/m³] (H2 share <10%)
0...4,000ppm / 1ppm
±20ppm (0...400ppm), ±5% of reading (401...1,000ppm), ±10% of reading (1,001...4,000ppm) / t90 <60s
Carbon monoxide, via internal electro-chemical sensor (only 327-2 with option COH2):
CO content [ppm, mg/m³]
0...8,000ppm / 1ppm
±20ppm (0...200ppm), ±5% v. Mw. (201...2,000ppm), ±10% of reading (2001...8,000ppm) / t90 <40s
Ambient Carbon monoxide, via internal electro-chemical sensor:
Ambient CO content amCO [ppm]
0...2,000ppm / 1ppm
±10ppm (0...100ppm), ±10% of reading (>100ppm) / t90 <40s
Temperature, via type K thermocouple of flue gas probe (NiCr-Ni):
Flue gas temperature FT, Flue gas dew point ATP, Ambient air AT
-40...+600°C / 0.1°C, -40...1,112°F / 0.1°F
±0.5°C (-40...100°C), ±0.5% of reading (>100°C), ±0.9°F (-40...212°F), ±0.5% of reading (>212°F) / t98 <50s (TE 0.5mm);<100s (TE 1mm)
Temperature, via differential temperature set 0554 1208:
Flue gas socket T1 [°C, °F], Sensor socket T2 [°C, °F]
Pressure, via internal differential pressure sensor:
Flue draught Drght [mbar, hPa, inW, in Hg]
-40...40hPa / 0.01hPa
±0.02hPa (-0.50...0.60hPa), ±0.03hPa (0.61...3hPa), ±1.5% of reading (>3hPa) /-
Flue draught Drght, with option of precision draught [Pa] -100...100Pa / 0.1Pa
±3Pa / -
Pressure and tightness test via internal differential pressure sensor, with differential pressure set 0554 1203:
Differential pressure Δp [hPa] -200...200hPa / 0.1hPa (with option precision difference pressure: 0.01hPa)
±0.5hPa (0.0...50.0hPa) ±1% of reading (50.1...100.0hPa) ±1.5% of reading (100.1...200.0hPa)
Efficiency, calculated:
Efficiency η2 [%], Efficiency η+3) [%]
0...120% / 0.1%
±0.2% / -
WarrantyMeasuring instrument 36 monthsflue gas probe 24 monthsMeasuring cells 36 monthsThermocouple 12 monthsRechargable battery 12 months